1. Home
  2. ›Laser Safety
  3. ›Ultrafast Laser Safety Calculator

Ultrafast Laser Safety Calculator

Eye safety of femtosecond and picosecond lasers on the ICNIRP 2013 limits: sub-ns single-pulse limits, the average-power rule that governs MHz trains, eyewear OD and NOHD.

Model: Textbook approximation

Educational only — not compliance-grade

These pages implement the published exposure limits for the cases each one states, but they are educational tools: no laser safety officer has signed them off.

  • Do not use these results alone for PPE selection, NHZ / NOHD approval, controlled-area sign-off, enclosure/interlock approval, or formal classification.
  • Always verify against ANSI Z136.1, IEC 60825-1, your local procedures, and the responsible laser safety officer / CLSO.

Average power

1.00 W

Peak power E/τ: 1.25e+5 W

Max energy per pulse

7.72 pJ

Retina, thermal, average power

Eyewear OD needed

3.21

At the output, 10.0 s. The single-pulse rule alone would call it safe

NOHD

396 m

Direct beam, diameter a + rφ

Limit1. Single pulse2. Pulse groups (average)3. C_P × single pulseMax per pulseYour pulse / max
Retina, thermal38.5 nJ7.72 pJfull train: 8.00e+8 pulses38.6 pJC_P = 0.133, n = 2.00e+6 groups of 400 pulses in T_i7.72 pJ1620× (exceeds)
Anterior eye (skin limit, 2 × in the IR)611 nJ747 pJfull train: 8.00e+8 pulses—747 pJ16.7× (exceeds)

Energies per pulse in the beam (1/e² Gaussian, averaged over each limit's aperture). Rule 3 applies to the retinal thermal limit only; "—" means the rule doesn't apply (rule 2 needs two pulses).

A mode-locked oscillator puts tens of millions of pulses into the eye each second, so the average power, not the single pulse, sets the limit: ICNIRP 2013's rule 2 holds every group of pulses to the limit for the time it spans, up to the whole exposure. Pulses closer together than T_i (5 µs below 1050 nm, 13 µs above) also count as one pulse for the C_P rule. The single-pulse limits below 1 ns are ICNIRP 2013 Table 5's: 1 mJ/m² over the 7 mm pupil from 100 fs to 10 ps (× C_C above 1050 nm; no C_A), 2 C_A mJ/m² from 10 ps (20 C_C mJ/m² at 1050–1400 nm); shorter than 100 fs, and on the cornea below 1 ns, the irradiance is held at the shortest tabulated value. For the cornea (below 400 nm and above 1400 nm) ICNIRP 2013 (p. 287) also advises, as a conservative interim guideline, keeping sub-ns exposures below 10 % of the 1 ns limit; the page applies it. A beam under 1 mm (1/e diameter, d/√2 for the 1/e² d) is held to its peak on the cornea below 0.35 s (ICNIRP 2013 Table 5 note c).

Below 10 ps the retina is damaged by non-linear effects (laser-induced breakdown) rather than heat, which is why ICNIRP drops C_A there; it states that its limits also preclude non-linear injury. Eyewear for ultrafast lasers must keep its OD at the peak power: absorbing filters can saturate or bleach, so EN 207 tests mode-locked lasers separately ("M"). Use 0.25 s for an accidental glance at a visible beam and 10 s for the near infrared. Not modelled: pulse bursts, supercontinuum and harmonic lines (see the multiple-wavelength page), atmospheric attenuation, focusing optics.

Largest energy per pulse against the repetition rate at the output, for this pulse duration and exposure. Which rule binds depends on the train: for exposures longer than 0.25 s the C_P rule usually binds first as the rate rises, then the group (rule 2) rule at high rates.

Model and references

Textbook approximation. A standard approximation from the literature (for example paraxial, plane-wave or Gaussian-beam), valid within the range the page states. About the tiers

ICNIRP 2013 repetitive-pulse rules with the sub-ns rows (1 mJ/m² from 100 fs to 10 ps; the cornea below 10 % of its 1 ns limit, p. 287); round Gaussian beam over each aperture, NOHD with a + rφ. Not modelled: bursts, harmonics, eyewear saturation.

  1. ICNIRP (2013). Guidelines on limits of exposure to laser radiation of wavelengths between 180 nm and 1,000 µm. Health Phys. 105(3), 271–295. Repetitive pulse exposures (p. 287), Tables 4, 5 and 8. doi:10.1097/HP.0b013e3182983fd4
Report a problem

A wrong value, a formula, a reference, or a page that misbehaves. The report includes this page and its current inputs.