1. Home
  2. ›Laser Safety
  3. ›Eye-Safe Wavelength Region

Eye-Safe Wavelength Region

Largest energy per pulse within the ICNIRP 2013 eye limits across the spectrum for your pulse width, repetition rate and beam: why 1.4–2.6 µm lasers are called eye-safe, and how a pulse train narrows the margin.

Model: Exact

Educational only — not compliance-grade

These pages implement the published exposure limits for the cases each one states, but they are educational tools: no laser safety officer has signed them off.

  • Do not use these results alone for PPE selection, NHZ / NOHD approval, controlled-area sign-off, enclosure/interlock approval, or formal classification.
  • Always verify against ANSI Z136.1, IEC 60825-1, your local procedures, and the responsible laser safety officer / CLSO.
Laserλ (nm)Limited byMax energy per pulseYour pulse / max
Nd:YAG ×3355Cornea (UV) (single pulse)572 µJ175× (exceeds)
Nd:YAG ×2532Retina, thermal (single pulse)78.5 nJ1.27e+6× (exceeds)
Diode (lidar)905Retina, thermal (single pulse)202 nJ4.95e+5× (exceeds)
Nd:YAG1064Retina, thermal (single pulse)785 nJ1.27e+5× (exceeds)
Er fiber1550Cornea (IR) (average)1.56 mJ64.3× (exceeds)
Ho / Tm2050Cornea (IR) (average)1.55 mJ64.7× (exceeds)
CO₂10600Cornea (IR) (single pulse)1.02 mJ97.9× (exceeds)

Why 1.4–2.6 µm is called "eye-safe": up to 1400 nm the eye focuses the beam on the retina, so the single-pulse limit is a few mJ/m² over the 7 mm pupil (2 mJ/m² × C_A below 5 µs; 20 mJ/m² × C_C from 1050 nm below 13 µs). From 1400 nm water in the cornea absorbs the beam, nothing reaches the retina, and the limit is the corneal one: 10³ J/m² below 1 ms (10⁴ J/m² at 1.5–1.8 µm), averaged over 1 mm. That is 10⁴–10⁶ times more energy for the same beam. "Eye-safe" is relative: a pulse above the corneal limit still burns the cornea. A train lowers the limit per pulse: ICNIRP's repetitive-pulse rules hold every group of pulses to the limit for the time it spans (the average power) and, on the retina, reduce the single-pulse limit by C_P; the "Limited by" column names the rule that binds. Above 1400 nm only the single-pulse and average rules apply, so at higher repetition rates the corneal average limit takes over. Limits from ICNIRP 2013 (Health Phys. 105:271, Tables 3, 5 and 8, repetitive pulses p. 287, with the sub-ns rows) and a round Gaussian beam centred on the aperture. A beam under 1 mm (1/e diameter, d/√2 for the 1/e² d) is held to its peak on the cornea below 0.35 s (ICNIRP 2013 Table 5 note c). The pulsed MPE page shows the rules in detail.

Largest energy per pulse of this width, repetition rate and beam within the eye limits, 180 nm to 20 µm, for the train and (dotted) one pulse.

Model and references

Exact. The equations are exact within the stated assumptions, or are a standard's tabulated values. The results are as good as the inputs. About the tiers

ICNIRP 2013 point-source eye limits with the repetitive-pulse rules (single pulse, pulse groups, C_P) and the sub-ns rows; round Gaussian beam averaged over each aperture (its peak if under 1 mm (1/e) on the cornea below 0.35 s, ICNIRP Table 5 note c).

  1. ICNIRP (2013). Guidelines on limits of exposure to laser radiation of wavelengths between 180 nm and 1,000 µm. Health Phys. 105(3), 271–295. Tables 3, 5 and 8; repetitive pulse exposures (p. 287). doi:10.1097/HP.0b013e3182983fd4
Report a problem

A wrong value, a formula, a reference, or a page that misbehaves. The report includes this page and its current inputs.