Raman Shift Calculator
Convert between Raman shift (cm⁻¹) and Stokes or anti-Stokes wavelength for any laser, with the vibrational energy and the anti-Stokes/Stokes ratio.
Stokes line λ_S
561.893 nm
17796.99 cm⁻¹
Anti-Stokes line λ_aS
505.127 nm
19796.99 cm⁻¹
Laser wavenumber ν̃_L
18796.99 cm⁻¹
Vibrational energy hcΔν̃
123.984 meV
Frequency cΔν̃ = 29.979 THz
Anti-Stokes/Stokes ratio at 295 K
0.01049
Photon counts, m = 3
Shift of a line at 561.89 nm
999.9 cm⁻¹
Stokes side
All wavelengths are vacuum values. Spectrometers calibrated in air read about 0.15 nm shorter at 532 nm (n_air ≈ 1.00028), which moves a shift by under 1 cm⁻¹ when the laser and the line are read the same way.
Scattered wavelength vs Raman shift
- Stokes
- Anti-Stokes
- Current shift
Common Raman bands at 532.0 nm
| Band | Shift (cm⁻¹) | Stokes λ (nm) | Anti-Stokes λ (nm) |
|---|---|---|---|
| Silicon, optical phonon | 520.7 | 547.16 | 517.66 |
| Cyclohexane, ring breathing | 801.3 | 555.69 | 510.25 |
| Diamond, optical phonon | 1332 | 572.57 | 496.80 |
| Graphite, G band | ≈ 1580 | 580.82 | 490.75 |
| C=O stretch | ≈ 1700 | 584.90 | 487.88 |
| CH₂ symmetric stretch | ≈ 2850 | 627.08 | 461.96 |
| O–H stretch, liquid water (broad) | ≈ 3400 | 649.48 | 450.51 |
Silicon, cyclohexane and diamond are shift-calibration standards; ≈ marks typical group frequencies, which move with the molecule and its surroundings. The graphite D band near 1350 cm⁻¹ moves with the laser wavelength.
ν̃_L = 10⁷/λ_L (cm⁻¹, λ in nm)
Stokes: ν̃_S = ν̃_L − Δν̃, λ_S = 10⁷/ν̃_S
Anti-Stokes: ν̃_aS = ν̃_L + Δν̃, λ_aS = 10⁷/ν̃_aS
I_aS/I_S = (ν̃_aS/ν̃_S)^m · exp(−hcΔν̃/k_BT), m = 3 (photons) or 4 (power)
The shift is the vibrational wavenumber of the molecule, so it does not depend on the laser; the scattered wavelengths do. The anti-Stokes line starts from the thermally populated excited level, which makes it weaker and the ratio a thermometer. The ratio assumes a harmonic vibration and equal cross-sections on both sides, which fails under resonance excitation.
Model and references
Exact. The equations are exact within the stated assumptions, or are a standard's tabulated values. The results are as good as the inputs. About the tiers
Exact conversions by energy conservation, in vacuum wavelengths. The anti-Stokes/Stokes ratio assumes a harmonic vibration in thermal equilibrium and equal Raman cross-sections on both sides (not under resonance excitation).
- Long D. A. (2002). The Raman Effect: A Unified Treatment of the Theory of Raman Scattering by Molecules. Wiley. Stokes and anti-Stokes intensities and their temperature dependence. doi:10.1002/0470845767
- McCreery R. L. (2000). Raman Spectroscopy for Chemical Analysis. Wiley. Raman shift standards (silicon, cyclohexane, diamond). doi:10.1002/0471721646
Report a problem
Related calculators
Surface-Enhanced Raman Spectroscopy (SERS)
Electromagnetic SERS enhancement factor of a silver nanosphere: local field, maximum and surface-averaged |E|⁴ enhancement, resonance and distance decay.
Coherent Raman (CARS/SRS) Calculator
Coherent anti-Stokes Raman scattering (CARS) and stimulated Raman scattering (SRS): wavelengths, focal intensity, lineshapes and excitation bandwidth.
Stimulated Raman Scattering Microscopy Calculator
Shot-noise-limited SNR, detection limit, Stokes wavelength, resolution and frame time for stimulated Raman scattering microscopy.