1. Home
  2. ›Imaging
  3. ›Cleared Tissue Imaging Calculator

Cleared Tissue Imaging Calculator

Cleared tissue imaging: ballistic light fraction with depth, resolution, and the focal shift from an index mismatch.

Model: Textbook approximation

Results

Lateral resolution λ/(2NA)283 nm
Axial FWHM, widefield PSF (index-matched)1.019 µm
Ballistic fraction at depth60.0 %
Ballistic loss2.2 dB
Scattering length 1/µ_s2.00 mm
Depth to 1/e (1/µ_t)1.96 mm
Depth to 1 %9.03 mm
Focal shift factor, paraxial n_s/n_imm1.000×
Focal shift factor, marginal ray1.000×

Ballistic fraction vs depth

Model

Ballistic fraction = exp(−(µ_a + µ_s) z)

Axial FWHM = 0.88 λ/(n_s − √(n_s² − NA²)); lateral = λ/(2NA)

Focal shift: n_s/n_imm (paraxial) to tan α_imm/tan α_s (marginal ray), sin α = NA/n

Clearing lowers µ_s by matching the refractive indices inside the tissue; the default µ_a and µ_s are example values for a well-cleared sample, not measured data. The ballistic fraction is the unscattered light that still forms a sharp focus, one way at this wavelength; scattered light adds a diffuse background and is not counted. The resolution figures hold for an objective matched to the sample. When n_imm ≠ n_s, the focus moves by a factor between the two shift factors per unit of stage travel (scale z-stacks by it), and spherical aberration broadens the PSF with depth, which this page does not model.

Model and references

Textbook approximation. A standard approximation from the literature (for example paraxial, plane-wave or Gaussian-beam), valid within the range the page states. About the tiers

Beer–Lambert attenuation of ballistic light only (scattered light is not counted). Resolution assumes an index-matched objective; the mismatch focal shift is bounded by the paraxial and marginal-ray factors, and spherical aberration is not modelled. Default µa and µs are examples.

  1. Jacques S. L. (2013). Optical properties of biological tissues: a review. Phys. Med. Biol. 58, R37–R61. Absorption and scattering coefficients. doi:10.1088/0031-9155/58/11/R37
  2. Richardson D. S., Lichtman J. W. (2015). Clarifying tissue clearing. Cell 162, 246–257. Refractive-index matching and scattering in cleared tissue. doi:10.1016/j.cell.2015.06.067
  3. Hell S., Reiner G., Cremer C., Stelzer E. H. K. (1993). Aberrations in confocal fluorescence microscopy induced by mismatches in refractive index. J. Microsc. 169, 391–405. Focal shift. doi:10.1111/j.1365-2818.1993.tb03315.x
  4. Diel E. E., Lichtman J. W., Richardson D. S. (2020). Tutorial: avoiding and correcting sample-induced spherical aberration artifacts in 3D fluorescence microscopy. Nat. Protoc. 15, 2773–2784. Paraxial and marginal-ray focal-shift factors. doi:10.1038/s41596-020-0360-2
  5. Born M., Wolf E. (2019). Principles of Optics, 7th ed., §8.8. Cambridge University Press. Axial PSF of a uniformly filled pupil. doi:10.1017/9781108769914